Product Details:
Brand | BOSCH |
Mike Set Type | Wired |
Mixer Type | Powered Mixer |
Wireless | No |
Amplifier Power | 500 watt |
Voltage | 100 to 240 VAC +-10%,50/60 Hz |
Air pressure | 600 to 1100 h Pa |
Phantom supply | 12 V +-1 V @ 15 mA |
Power consumption | Pmax -3 dB* / idle** / standby |
Rated load capacitance | 125 nF (100 V); 250 nF (70 V) |
Rated load resistance | 80 ohm (100 V); 40 ohm (70 V) |
Rated output power (per channel) | 250 W (1 min. at 55 degC) 125 W (30 min. at 55 degC,cont. at 30 degC) 60 W (cont. at 55 degC) |
Relative humidity | 15% to 90% |
S/N | 62 dBA with 25 dB headroom |
Storage temperature | -40 degC to +70 degC (-40 degF to +158 degF) |
Weight LBB 4421/10 | 13 kg (28.7 lb) |
CMRR | 40 dB at 1 kHz |
in front of brackets | 40 mm (1.6 in) |
Connector | 6-pole header for removable screw connector (mono,balanced) |
Dimensions (H x W x D) | 92 x 440 x 400 mm (3.6 x 17.3 x 15.7 in) |
Frequency response | -3 dB @ 100 Hz and 16 kHz |
Input impedance | 1360 ohm |
Input range | -7 dBV to +8 dBV ref nominal input value |
Nominal input level | -57 dBV |
Operating temperature | -5 degC to +55 degC (+23 degF to +131 degF) |
Interconnections
Additional Information:
Product Details:
Brand | BOSCH |
Color | Charcoal with silver |
Output Impedance | 100 ohm |
Humidity | 15% to 90% |
Connectors | XLR and stereo cinch (for each line) |
Voltage | 48 Vdc -10% to +20% |
Mounting | Standalone; 19" rack |
Weight | 7 kg (15.4 lb) |
Connector | 3-pin XLR |
Crosstalk | -85 dB |
Input Impedance | 1360 ohm |
Nominal Input Level | -57 dBV |
Operation | Closing contact (with supervision) |
Air pressure | 600 to 1100 hPa |
Input range | -7 dB to 8 dB ref nominal input level |
Line inputs | 2 x |
Line outputs | 4 x |
Mic / line inputs | 2 x |
Operating temperature | -5 to +55 oC (+23 oF to +131 oF) |
CMRR | 55 dB at 100 Hz |
Phantom supply | 12 V +-1 V @ 15 mA |
Power consumption | 21 W with no load 160 W with maximum load |
S/N | 89 dBA at maximum level |
Signal range | -12 dBV to +18 dBV (XLR),-24 dBV to +6 dBV (cinch) |
Storage temperature | -40 to +70 oC (-40 oF to +158 oF) |
behind brackets | 360 mm (14.2 in) |
in front of brackets | 40 mm (1.6 in) |
in rack, with brackets | 88 x 483 x 400 mm (3.5 x 19 x 15.7 in) |
Control inputs | 8 x |
Control outputs | 5 x |
Dimensions (H x W x D) | 92 x 440 x 400 mm (3.6 x 17.3 x 15.7 in) |
Distortion at 1 kHz | 0.05% |
Frequency response | 20 Hz to 20 kHz (-3 dB) |
Additional Information:
Product Details:
Model Number | PRS xPxxx and LBB 4428/00 |
Type Of Product | Power amplifier |
Power | 500 watt |
Channel | 2, 4 |
Brand | BOSCH |
Color | Black gray |
Weight | 16 |
Dimension | 92 x 440 x 400 mm |
Additional Information:
Product Details:
Color | Charcoal |
Humidity | 15% to 90% |
External power supply | 18 to 56 VDC |
Dimensions (H x W x D) | 90 x 160 x 200 mm |
Weight | 0.95 kg (2.1 lb) |
Mounting | Tabletop |
Length of mic stem | 380 mm |
Operating temperature | -5 degC to +45 degC (+23 degF to +113 degF) |
Storage temperature | -20 degC to +70 degC (-4 degF to +158 degF) |
Air pressure | 600 to 1100 hPa |
Power consumption | 4.4 W (DC) excluding keypads |
Nominal acoustic input level | 75 to 90 dB SPL |
S/N | 60 dB at 85 dB SPL |
Frequency response | 340 Hz to 14 kHz (-3 dB) |
Loudspeaker S/N | 80 dB at max. output |
Sound pressure level | 85 dB (SPL) at 0.5 m and 1 kHz |
Headset Connector | 3.5 mm jack |
Recommended type | Hosiden HBH 0058 |
Functions
The call station has a cardioid, supervised microphone on a gooseneck stem with good speech intelligibility. A limiter and a speech filter improve intelligibility and prevent clipping of the audio. It has a volume control for the monitoring speaker and the headset. When it plays a chime or a pre-recorded message, the call station activates its speaker. When a headset is connected, it replaces the microphone and speaker. The call station has its own DSP, and converts between analog and digital audio. The audio
processing can include sensitivity adjustment, limiting, and parametric equalization. Up to 16 call station keypads can connect to the station via a serial communication link. The station provides the power for the keypads. Up to 224 priorities can be assigned to the call station. All configuration can be done via the Praesideo network controller. The call station is fully supervised and supports fail-safe operation. Even if the Praesideo network
controller fails, the call station is still able to put through emergency calls.
Controls and indicators
Interconnections
Additional Information:
Product Details:
Color | Charcoal |
External power supply | 18 to 56 VDC |
Power consumption | 2.9 W at 48 V without keypads |
Nominal acoustic input level | 75 to 90 dB SPL |
S/N | 80 dB at max. |
Frequency response | 340 Hz to 14 kHz (-3 dB) |
Sound pressure level | 85 dB (SPL) at 0.5 m and 1 kHz |
Connector | 3.5 mm jack |
Recommended type | Hosiden HBH 0058 |
Dimensions (H x W x D) | 90 x 160 x 200 mm (3.5 x 6.3 x 7.9 in) |
Length of goose neck | 380 mm (15 in) |
Weight | 1 kg (2.2 lb) |
Mounting | Standalone |
Operating temperature | -5 degC to +45 degC (+23 degF to +113 degF) |
Storage temperature | -20 degC to +70 degC (-4 degF to +158 degF) |
Humidity | 15% to 90% |
Air pressure | 600 to 1100 hPa |
Functions
The call station has a cardioid, supervised microphone on a
gooseneck stem with good speech intelligibility. A limiter and a speech filter improve intelligibility and prevent clipping of the audio. It has a volume control for the monitoring speaker and the headset. When it plays a chime or a pre-recorded message, the call station activates its speaker. When a headset is connected, it replaces the microphone and speaker. The remote call station connects via a CAT-5 cable to an LBB 4437/00 unit, which interfaces it to the Praesideo optical network. The station gets its power from the interface unit via the CAT-5 cable, but is also equipped with a local power supply connection for extreme cases with a very long cable and many keypads. Up to 16 call station keypads can connect to the station via a serial communication link. The call station provides the power for the keypads. Up to 224 priorities can be assigned to the call station. All configuration can be done via the Praesideo network controller. The remote call station is fully supervised and complies with IEC 60849. The call station supports fail-safe operation. Even if the Praesideo network controller fails, the call station is still able to put through emergency calls.
Controls and indicators
Interconnections
Additional Information: